{"id":108,"date":"2021-10-04T18:29:20","date_gmt":"2021-10-04T18:29:20","guid":{"rendered":"https:\/\/blog.decu.com.mx\/telecom\/?p=108"},"modified":"2021-10-04T18:40:55","modified_gmt":"2021-10-04T18:40:55","slug":"prueba-de-presion-deteccion-de-ruido-y-fuga-en-el-hogar","status":"publish","type":"post","link":"https:\/\/blog.decu.com.mx\/telecom\/prueba-de-presion-deteccion-de-ruido-y-fuga-en-el-hogar\/","title":{"rendered":"Prueba de Presi\u00f3n \u2013 Detecci\u00f3n de Ruido y Fuga en el Hogar"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Las Instalaciones Inteligentes, Solo se Hicieron M\u00e1s Inteligentes<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DECU Soluciones a trav\u00e9s de su representada Effigis\u00a0 \u2013 CPAT &amp; VeEX Inc. presenta: Una nota de aplicaci\u00f3n sobre los beneficios de adoptar un enfoque de prueba de la integridad del blindaje utilizando el\u00a0<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/kit-prueba-de-presion-fuga-leakage\/\">Kit\u00a0DRV3\u00a0\/ DSG1 Lite<\/a><\/strong>\u00a0de CPAT y\/o el\u00a0<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/medidores-de-campo\/medidor-de-campo-portatil-redes-docsis-cx310\/\">CX310<\/a><\/strong>\u00a0de<strong><a href=\"https:\/\/www.decu.com.mx\/etiqueta-producto\/veex-inc\/\">\u00a0VeEX<\/a><\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-Leakage-1.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-Leakage-1.png\" alt=\"\" class=\"wp-image-11744\"\/><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Eficacia De Protecci\u00f3n Del Equipo Pasivo En El Hogar<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En El documento t\u00e9cnico de Motorola titulado: Eficacia de Blindaje del Cableado y los Divisores de TV por Cable en el Hogar (<em>Shielding Effectiveness of In-Home Cable TV Wiring and Splitters<\/em>)&nbsp; indica que, un cable de alta calidad y bien terminado, exhibir\u00e1 suficiente efectividad de blindaje (SE \u2013&nbsp;<em>Shielding Effectiveness<\/em>) para evitar interferencias en campos de m\u00e1s de 10 voltios por metro (V \/ metro).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El mismo articulo concluye que un valor de SE de 100 dB corresponde al valor SE (Shielding Effectiveness) necesario para el umbral de interferencia para se\u00f1ales QAM 256 DTV, al m\u00ednimo nivel FCC requerido de -12dBmV, y un campo aplicado de 1 V\/m.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Seguimiento De Problemas Potenciales De La Integridad del Blindaje En El Cable<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>La Brecha entre la Planta Externa y la Premisa del Cliente \u2013 \u201cTap \u2013 Casa\u201d<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si bien los operadores tienen un control relativamente bueno sobre la planta externa en t\u00e9rminos de SE, podr\u00eda ser una historia bastante diferente en la premisa del cliente (Tap \u2013 Casa). Algunos clientes agregar\u00e1n un televisor o dos o conectar\u00e1n una habitaci\u00f3n reci\u00e9n construida con equipos pasivos no profesionales \u00f3 de baja calidad, como divisores y cables coaxiales terminados. En el documento t\u00e9cnico de Motorola, se demostr\u00f3 que el SE pod\u00eda diferir hasta 50 dB entre el equipo pasivo instalado por el operador del cable (cable coaxial de bajada y de instalaci\u00f3n dentro del hogar, divisores y acopladores) y el mismo tipo de equipo pasivo de menor calidad comprada e instalada por el cliente.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>El Ruido de Ingreso penetra a la red dom\u00e9stica donde la integridad del blindaje a sido comprometida<ul><li>Dispositivos viejos sin blindaje, conectores, conexiones sueltas, cable da\u00f1ado<\/li><li>El ingreso interrumpe el servicio y puede ocurrir de manera intermitente<\/li><li>Sin una forma efectiva de probarlo, habr\u00e1 llamadas de servicio reincidentes<\/li><li>Posible interrupci\u00f3n del servicio para varios clientes en el nodo afectado<\/li><\/ul><\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfComo Podemos Enfrentar este Problema?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Incremente la efectividad del blindaje en toda la planta mediante el uso de un enfoque preventivo, el cual deber\u00e1 agregar\u00e1 un proceso de control de calidad preventivo mientras su personal ya est\u00e1 en las instalaciones del cliente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Control de Calidad Preventivo con \u201cPrueba de Presi\u00f3n de Fuga\u201d.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El primer paso ser\u00eda utilizar el equipo pasivo de mejor calidad para aumentar el SE de su planta. Verificar qu\u00e9 tanto su su personal y contratistas hayan aplicado correctamente los procedimiento de instalaci\u00f3n de cables. El personal propio del operador debe descartar cualquier equipo pasivo no provisto por la empresa (equipos de bajo costos adquiridos por el propio cliente o por mala practica del contratista), ya que es probable que este equipo tenga un SE insuficiente contra interferencias.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una vez que se haya completado la instalaci\u00f3n de cable, la instalaci\u00f3n de un nuevo cliente o una llamada de servicio, agregue un paso proactivo a su procedimiento de servicio realizando una \u201c<strong>prueba de presi\u00f3n de fuga\u201d (Leakage)<\/strong>&nbsp;para asegurarse de que no haya fugas presente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esta prueba de presi\u00f3n de fuga (leakage pressure test) Se realiza aplicando un conjunto de portadoras con nivel alto de RF sobre el cable coaxial de la entrada (Drop \u2013 Cable\/ Cable hacia el interior del domicilio). Utilizando un receptor de fuga de cable, el personal recorrer\u00e1 cada habitaci\u00f3n en las instalaciones del cliente para asegurarse de que no haya fugas presentes antes de retirarse del domicilio del cliente, evitando as\u00ed una segunda visita.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El control de calidad en las instalaciones ha venido a ser a\u00fan mas importantes con el espectro LTE adicional que cae directamente en el espectro del cable de banda ancha.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>La Soluci\u00f3n<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>Mantenga a los clientes m\u00e1s felices no solo reduciendo el tiempo de trabajo sino aumentando la calidad del servicio<\/strong><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Certificaci\u00f3n en el hogar \u2013 Prueba de Presi\u00f3n<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La prueba de presi\u00f3n es una prueba fuera de servicio y no tiene impacto en la red.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Esta prueba permite que el t\u00e9cnico camine r\u00e1pidamente por la casa y verifique si hay fugas sin tener que conectar un medidor de se\u00f1al en cada punto de conexi\u00f3n y dispositivo CPE.<\/li><li>Una vez conectado, The Home Leakage Transmitter (<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-portatil-de-senal-digital-de-doble-banda-dsg1-lite\/\">DSG 1 Lite<\/a><\/strong>) inyecta una portadora CW etiquetada en dos frecuencias, 126 MHz y 612 MHz.<ul><li>Nota Importante: No inyecte la se\u00f1al etiquetada con RF presente<\/li><\/ul><\/li><li>Los niveles de la portadora inyectados son mucho m\u00e1s altos que los niveles del sistema, esto forzara al sistema de la acometida a mostrar las fugas presente.<\/li><li>Si hay un punto d\u00e9bil en el sistema de la acometida, la se\u00f1al saldr\u00e1 y ser\u00e1 detectada por el medidor<\/li><li>Esto es similar a presurizar una tuber\u00eda de agua.<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-Leakage-Ducto-Agua.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-Leakage-Ducto-Agua.png\" alt=\"\" class=\"wp-image-11745\"\/><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">El&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/detector-de-fugas-digital-portatil-drv3-lite\/\">DRV3 Lite<\/a><\/strong>&nbsp;es su medidor de doble-modo, de doble frecuencia \u201cAgil\u201d y un medidor digital port\u00e1til para b\u00fasqueda y reparaci\u00f3n de fugas (leakage). Puede operar ya sea en \u201c<strong>Modo de Prueba de Presi\u00f3n<\/strong>\u201d, detectando portadoras de alto nivel generadas por el generador de se\u00f1al port\u00e1til&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-portatil-de-senal-digital-de-doble-banda-dsg1-lite\/\">DSG1 Lite<\/a><\/strong>, o en \u201cModo Sistema\u201d, detectando portadores de fuga generados desde el generador de se\u00f1al&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-de-senal-digital-para-cabecera-dsg1\/\">DSG1&nbsp;<\/a><\/strong>ubicado en la cabecera. El t\u00e9cnico puede cambiar del sistema al modo de prueba de presi\u00f3n presionando un solo bot\u00f3n.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/App-Fuga-Modo-Presion.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/App-Fuga-Modo-Presion.png\" alt=\"\" class=\"wp-image-11746\"\/><\/a><\/figure><\/div>\n\n\n\n<ul class=\"wp-block-list\"><li>Aumenta la eficiencia al reducir los puntos de contacto<\/li><li>Mitigue los problemas de ingreso se\u00f1alando las fuentes de ingreso<\/li><li>Aseg\u00farese de que los dispositivos \/ blindaje sean adecuados y que el sistema est\u00e9 perfectamente blindado<\/li><li>Cierre el sistema a la interferencia LTE, sin fugas en LTE<\/li><li>Ayuda para habilitar velocidades de gigabit completas (m\u00e9tricas de EE. UU. \/ DS)<\/li><li>Prepare el hogar \/ MDU para futuras tecnolog\u00edas<\/li><li>Mantenga a los clientes m\u00e1s felices no solo reduciendo el tiempo de trabajo sino tambi\u00e9n aumentando la calidad del servicio<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Con su dise\u00f1o de doble sintonizador, el&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/detector-de-fugas-digital-portatil-drv3-lite\/\">DRV3 Lite<\/a><\/strong>&nbsp;proporciona una indicaci\u00f3n visual y de audio simult\u00e1nea de las fugas detectadas en las bandas de VHF y UHF, el ambos indicadores van incrementando a medida que se el t\u00e9cnico se va acercando a la fuente de la fuga (falla).<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Modo-Sistema.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Modo-Sistema.png\" alt=\"\" class=\"wp-image-11752\"\/><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Nuestro&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/kit-prueba-de-presion-fuga-leakage\/\">Kit DRV3 Lite<\/a><\/strong>&nbsp;&amp;&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-portatil-de-senal-digital-de-doble-banda-dsg1-lite\/\">DSG1 Lite<\/a><\/strong>&nbsp;o el&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-de-senal-digital-para-cabecera-dsg1\/\">DSG1&nbsp;<\/a><\/strong>garantiza la calidad total para instalaciones dom\u00e9sticas e instalaciones de vivienda multiple (MDU \u2013 Multiple Dwelling Units), mediante el seguimiento de posibles problemas de integridad del blindaje del cable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Este soluci\u00f3n proporciona una oportunidad efectiva y \u00fanica para que los t\u00e9cnicos de cumplimiento certifiquen de manera proactiva sus instalaciones antes de que se conviertan en costosas llamadas de servicio.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/App-Fuga-Kit-DVR3-y-DSG1-.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/App-Fuga-Kit-DVR3-y-DSG1-.png\" alt=\"\" class=\"wp-image-11747\"\/><\/a><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">VeEX Inc \u2013 Pressure Testing \u2013 HIP Certification<\/h2>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-CX310-Deteccio%CC%81n-de-Fuga-e-Ingreso-en-la-Red.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-CX310-Deteccio%CC%81n-de-Fuga-e-Ingreso-en-la-Red.png\" alt=\"\" class=\"wp-image-11748\"\/><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">VeEX Inc ha introducido al mercado de Televisi\u00f3n Por Cable su&nbsp; Herramienta de instalaci\u00f3n \u2013&nbsp; DOCSIS 3.1&nbsp; \u2013 CX310, un medidor liviano, ultra-port\u00e1til y de bajo costo equipado con un cable m\u00f3dem DOCSIS 3.1. Este equipo soporta an\u00e1lisis real OFDM y mediciones de rendimiento VeTest (Pruebas de Rendimiento en Capa 4). Las caracter\u00edsticas clave de SLM incluyen un Single Channel, VeCheck Full Band Scan y Ingress Scan.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una de sus herramientas que soporta este equipo es&nbsp; \u201cThe Home Installation Process (HIP) Auto test\u201d, la cual habilita, en conjunto con el&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-portatil-de-senal-digital-de-doble-banda-dsg1-lite\/\">DSG1 Lite<\/a><\/strong>&nbsp;(Modo Presi\u00f3n) la Certificaci\u00f3n En El Hogar conforme un procedimiento de prueba ya sea Manual o bajo la aplicaci\u00f3n HIP Pressure Testing Certification<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/App-Fuga-VeEX-Prueba-Manual.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/App-Fuga-VeEX-Prueba-Manual.png\" alt=\"\" class=\"wp-image-11750\"\/><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Una de las ventajas del&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/medidores-de-campo\/medidor-de-campo-portatil-redes-docsis-cx310\/\">CX310<\/a>&nbsp;<\/strong>bajo la aplicaci\u00f3n HIP Pressure Testing Certification, una vez concluida esta prueba y salvado los resultados, estos mismo resultados pueden ser actualizados al Sistema de Flujo de Trabajo&nbsp;R-Server&nbsp;de VeEX para su almacenamiento en el sistema.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-CX310-HIP-Pressure-Testing-Certification.png\"><img decoding=\"async\" src=\"https:\/\/www.decu.com.mx\/wp-content\/uploads\/2019\/11\/APP-Fuga-CX310-HIP-Pressure-Testing-Certification.png\" alt=\"\" class=\"wp-image-11751\"\/><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">No hay criterio para un Pasa\/Falla en la prueba de presi\u00f3n, el \u00fanico requerimiento es que la prueba (con el equipo&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/medidores-de-campo\/medidor-de-campo-portatil-redes-docsis-cx310\/\">CX310&nbsp;<\/a><\/strong>de VeEX) sea realizada con la herramienta HIP (Home Installation Process) y posterior a la prueba, se salven y se suban los datos.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Todo el tiempo de la Prueba de Presi\u00f3n ser\u00e1 grabada sobre la prueba de HIP, grabada y reportada al&nbsp;R-Server.<\/li><li>Si en el recorrido se encuentra alguna se\u00f1al RF de Fuga (Leakage), la reparaci\u00f3n debe ser realizada.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Caracter\u00edsticas y Beneficios<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><u>Programa de Certificaci\u00f3n en el Hogar (Prueba de Presi\u00f3n Ingreso\/Fuga)<\/u><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Reduce las llamadas repetitivas de servicios, ya que la mayor\u00eda de los problemas sobre la integridad del blindaje se generan desde las instalaciones del cliente (La Acometida)<\/li><li>Reduce la tasa de llamadas reincidentes de servicio y el costo impl\u00edcito, solucionando problemas desde la primera visita.<\/li><li>Valida la productividad del t\u00e9cnico instalador y\/o subcontratista con nuestras marcas de tiempo de la aplicaci\u00f3n m\u00f3vil CPAT.<\/li><li>Aumenta la visibilidad de los problemas en el hogar con un proceso de detecci\u00f3n y reparaci\u00f3n documentado y con sello de tiempo.<\/li><li>Aumenta su efectividad identificando ruido ascendente (\u201cIngress\u201d)\/ Fuga (\u201cLeakage\u201d) usando se\u00f1ales de pruebas de alto nivel.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><u>Modo Dual de Prueba de Fuga (Leakage)<\/u><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Modo Sistema: detecta las portadoras de fugas generados desde el&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-de-senal-digital-para-cabecera-dsg1\/\">DSG1&nbsp;<\/a><\/strong>ubicado en la cabecera.<\/li><li>Modo de Prueba de Presi\u00f3n: detecta las portadoras de alto nivel generadas por&nbsp;<strong><a href=\"https:\/\/www.decu.com.mx\/tienda\/television-por-cable-catv\/sistema-de-monitoreo-de-retorno-reverse-forward\/generador-portatil-de-senal-digital-de-doble-banda-dsg1-lite\/\">DSG1 Lite<\/a><\/strong>&nbsp;port\u00e1til.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aplicaci\u00f3n&nbsp;M\u00f3vil<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Gesti\u00f3n de tickets de reparaci\u00f3n en tiempo real.<\/li><li>Crear eventos en modo OFF-LINE (sin cobertura m\u00f3vil de servicio).<\/li><li>Mediciones antes y despu\u00e9s de la reparaci\u00f3n<\/li><li>Habilidad de cerrar eventos de Fuga (Leakage)<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">CPAT Aplicaci\u00f3n WEB<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Permite a usuarios autorizados ilimitados iniciar sesi\u00f3n en la aplicaci\u00f3n de servidor CPAT basada en la web.<\/li><li>Muestra una vista en tiempo real de los eventos de fuga \/ ingreso, lo que hace que su programa de mantenimiento preventivo sea m\u00e1s eficiente al acortar el ciclo de vida de eventos de fuga \/ ingreso y reducir la cantidad de llamadas de servicio.<\/li><li>Almacena datos en un formato abierto para facilitar informes personalizados e integraci\u00f3n con otros sistemas.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Si desea experimentar la soluci\u00f3n de detecci\u00f3n de ingreso y fuga de CPAT FLEX y el valor que puede aportar a su red de cable, ll\u00e1menos o escr\u00edbanos.&nbsp;Nuestros especialistas estar\u00e1n encantados de responder a todas sus preguntas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Fin de la nota de aplicaci\u00f3n.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Las Instalaciones Inteligentes, Solo se Hicieron M\u00e1s Inteligentes DECU Soluciones a trav\u00e9s de su representada Effigis\u00a0 \u2013 CPAT &amp; VeEX Inc. presenta: Una nota de aplicaci\u00f3n sobre los beneficios de &hellip;<\/p>\n<p class=\"read-more\"> <a class=\" thunk-readmore button \" href=\"https:\/\/blog.decu.com.mx\/telecom\/prueba-de-presion-deteccion-de-ruido-y-fuga-en-el-hogar\/\"> <span class=\"screen-reader-text\">Prueba de Presi\u00f3n \u2013 Detecci\u00f3n de Ruido y Fuga en el Hogar<\/span>Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":110,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[38],"tags":[43,46,40,44,45,42,41,39,47,15,10],"class_list":["post-108","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sistema-de-t-v-por-cable","tag-cpat","tag-cx310","tag-deteccion-de-ruido","tag-drv3","tag-dsg1-lite","tag-effigis","tag-fuga-en-el-hogar","tag-prueba-de-presion","tag-tv","tag-veex","tag-veex-inc"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/posts\/108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/comments?post=108"}],"version-history":[{"count":2,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/posts\/108\/revisions"}],"predecessor-version":[{"id":111,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/posts\/108\/revisions\/111"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/media\/110"}],"wp:attachment":[{"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/media?parent=108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/categories?post=108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.decu.com.mx\/telecom\/wp-json\/wp\/v2\/tags?post=108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}